Hygrometer readings explained: what your indoor humidity number means and what it misses

How to read a hygrometer: what indoor humidity numbers mean, why walls are damper than the room reading, where to place it and how to check it with salt.

About 6 minutes to read

In short

  • A hygrometer measures the relative humidity of the air where it sits. Guidance differs slightly by country: the US EPA advises keeping indoor humidity below 60%, ideally 30–50% [1]; Germany’s Federal Environment Agency recommends 40–60% [2].
  • Relative humidity depends on temperature. The same air that reads 50% in the middle of a 20 °C (68 °F) room reaches about 64% next to a 16 °C (61 °F) external wall and 80% in a 12.6 °C (55 °F) corner (worked example below). That is why a room reading says little about the spot where mould grows.
  • Cheap hygrometers can be well off: a German consumer test of 24 devices found deviations of up to 20% [3]. A simple salt test shows whether a device is roughly right.
  • One reading is a snapshot. For mould risk, what counts is how often and how long humidity stays high, especially overnight and after showers or cooking.

The symptom: a single number, many wrong conclusions

Hygrometers sit on bedroom shelves and windowsills in millions of homes, and their display is read as a verdict: 55%, all fine; 68%, mould alert. Both conclusions can be wrong.

For landlords, letting agents and property managers this matters more than it seems. In disputes about damp and mould, hygrometer photos are often presented as evidence. What they prove depends on where, when and with what device the reading was taken.

Why relative humidity changes with temperature

Warm air can hold more water vapour than cold air. Relative humidity (RH) is the share of that maximum actually present. When the same air cools down, with no water added or removed, its relative humidity rises.

Worked example: the same air in different places

Worked example (own calculation with the Magnus formula): room air at 20 °C and 50% RH holds about 8.6 g of water per cubic metre. As it cools at a surface, its RH rises:

Temperature at the spotRH of the same air
22 °C / 72 °F (near a radiator)44%
20 °C / 68 °F (middle of the room)50%
18 °C / 64 °F57%
16 °C / 61 °F (cold external wall)64%
14 °C / 57 °F73%
12.6 °C / 55 °F (cold corner)80%

Table 1: Relative humidity of the same air at different temperatures. Own calculation.

Bar chart: the same room air reads 44% near a radiator, 50% mid-room, 64% at a cold external wall and 80% in a 55 °F corner

Figure 1: Relative humidity of the same room air at a radiator, mid-room, an external wall and a cold corner. Own calculation.

Mould grows on surfaces, not in room air. It can start once the surface humidity sits around 70–80% for several days [4]. So a hygrometer in the warm middle of a room can show a comfortable 50% while conditions behind a wardrobe on an external wall already allow mould. How such cold spots form is explained in thermal bridges: cold spots, condensation and mould.

Common mistakes

  1. Wrong place: on a radiator shelf, on the windowsill, in direct sun or next to the kettle. Better: mid-room at roughly head height when seated, away from external walls and heat or moisture sources.
  2. Reading only in the daytime: the highest values often occur at night in bedrooms and straight after showers.
  3. Trusting one number: a reading taken after airing the room says little about the hours before.
  4. Never checking the device: dial (mechanical) hygrometers need checking and adjusting before first use [3]; electronic sensors can drift as they age.
  5. Ignoring temperature: without the temperature at the same spot, an RH value is only half the story.

Types of hygrometer

DevicePrincipleStrengthsLimits
Dial (hair or synthetic fibre)Fibre length changes with humidityNo battery, decorativeSlow, needs adjusting; some very inaccurate in tests [3]
Digital thermo-hygrometerCapacitive sensorTemperature and RH, often min/maxNo history; quality varies widely [3]
Data loggerStores readings at intervalsHistory over days and weeksNeeds downloading and analysis
Connected indoor climate sensorSends readings to a platform continuouslyHistory, several rooms, alerts at thresholdsInstallation and platform needed

Table 2: Hygrometers and humidity monitors compared.

The salt test

Above a saturated solution of ordinary table salt (sodium chloride) in a closed container, the air settles at about 75% RH; laboratories use this fixed point to calibrate humidity sensors [5]. Mix a few spoonfuls of salt with a little water into a damp paste, put it with the hygrometer in an airtight box or zip bag and wait several hours at a steady room temperature. A reading far from 75% means the device is off. The test does not replace calibration, but it catches gross errors.

The salt test in four steps: make a damp salt paste, seal it with the hygrometer in an airtight box, wait several hours, read; it should show about 75%

Figure 2: The salt test in four steps. Own illustration based on [5].

Better: from a single reading to a picture over weeks

  1. Place it properly: mid-room, away from heat, moisture and external walls.
  2. Read at different times: on waking, after showers and cooking, in the evening.
  3. Read temperature too: in a cool room, the same RH is more critical for walls.
  4. Ventilate in short bursts: in the cold season, open windows wide for a few minutes several times a day rather than leaving them tilted for hours [2].
  5. For recurring damp, monitor over weeks: in several rooms, with history, ideally including the problem wall.

How Nebatic helps

Nebatic measures temperature, humidity and CO₂ continuously in several rooms and shows the history over days and weeks. It shows when humidity rises, how long it stays high and whether ventilation works. CO₂ adds when a room is occupied and when it is aired. See preventing mould by monitoring humidity and finding the cause of mould.

Nebatic does not replace a survey. In a dispute, the data helps surveyors, landlords and occupants settle the cause objectively.

Risks and limits

  • Room air is not the wall: a hygrometer measures air where it sits. Cold spots need surface temperatures.
  • Measurement uncertainty: low-cost devices can be well off [3]. Surveys use calibrated instruments.
  • Not too dry either: long periods below about 40% are often felt as uncomfortable; see office humidity in winter.
  • Medical advice: if occupants have complaints that may be linked to damp or mould, they should see a doctor.

Hygrometer: quick answers

What should a hygrometer read indoors?

The US EPA recommends below 60%, ideally 30–50% [1]; Germany’s Federal Environment Agency recommends 40–60% [2]. Read temperature as well: cooler rooms make the same humidity more critical at walls.

Where should I put a hygrometer?

In the middle of the room, away from external walls, windows, radiators, showers and cookers.

How accurate are home hygrometers?

It varies widely. A German consumer test of 24 devices found deviations of up to 20% [3]. The salt test reveals gross errors.

How do I calibrate a hygrometer at home?

Use the salt test: seal the device with damp table salt in an airtight container for several hours. It should read about 75% [5]. Dial hygrometers can then be adjusted.

Does a hygrometer show mould risk?

Only indirectly. Mould starts on cold surfaces, where humidity is higher than in the middle of the room. A history over weeks and the temperature at the problem spot tell you more than a single reading.

Sources

  1. US EPA: Mold Course Chapter 9 (indoor humidity below 60%, ideally 30–50%). https://www.epa.gov/node/58723
  2. Umweltbundesamt: How to ventilate correctly (German). https://www.umweltbundesamt.de/themen/gesundheit/umwelteinfluesse-auf-den-menschen/schimmel/wie-luefte-ich-richtig-tipps-tricks-zur
  3. Stiftung Warentest (test 03/2003): Many humidity meters show wrong readings (German). https://www.test.de/presse/pressemitteilungen/test-Maerz-2003-Warnung-vor-Schimmelpilzgefahr-Viele-Luftfeuchtigkeitsmesser-zeigen-falsche-Messwerte-an-1089951-0/
  4. Bavarian State Office for the Environment (LfU), Ökoenergie-Institut Bayern (2016): Physical background of mould (German). https://www.energieatlas.bayern.de/sites/default/files/Physikalische_Hintergruende_Schimmel.pdf
  5. Greenspan, L. (1977): Humidity Fixed Points of Binary Saturated Aqueous Solutions. Journal of Research of the National Bureau of Standards 81A. https://nvlpubs.nist.gov/nistpubs/jres/81A/jresv81An1p89_A1b.pdf