Indoor air quality in offices: a good office works for people

Concentration needs more than a desk. Nebatic shows when air, temperature, light and noise affect working conditions, and helps improve rooms in a targeted way. At the same time, energy use and building operation can follow actual demand – instead of rigid schedules.

Offices
Employees

Monday to Friday in an office building

Occupancy, weather and meetings change what an office building needs from day to day, and often from hour to hour.

  1. Monday, 7:00

    Warm floors, nobody there

    The schedule has brought every floor up to full operation, but on Mondays many people work from home. Without room data, nobody notices that whole zones are being heated for no one.

  2. Tuesday, 10:30

    Third meeting, no break to air

    The small meeting room has been booked since the morning, with no gap to open the windows between sessions. The air turns stale long before anyone notices.

  3. Wednesday, 14:00

    Sunny side versus window seat

    On the south side heat builds up in the afternoon, while the window seat opposite gets a draught. Two tickets that may share one cause: a set point nobody has changed since commissioning.

  4. Thursday, 18:30

    Everyone gone, systems still on

    The last people have left, but ventilation and heating keep running to schedule. Whether that matches actual use only becomes clear when indoor climate and operating times are compared.

  5. Friday

    A weekly view instead of single complaints

    Facility management sees which rooms stood out repeatedly this week, and at what times. That makes it possible to adjust set points, schedules and room booking rules where it matters.

Questions from facility managers and landlords

Our building already has building automation – why add sensors?

Many systems measure at a few central points, such as a reference room or the extract duct. Nebatic shows what actually reaches individual meeting rooms and work areas, and brings in existing data from your building automation. This shows where the system and the room tell different stories.

Can tenants and landlords look at the same data?

Yes, if everyone involved wants that. Reports refer to rooms and areas, and the data can also be passed to a tenant portal or CAFM through interfaces. We agree with you which areas and reports are shared.

Does this reveal anything about individual employees?

Nebatic measures room conditions such as CO₂, temperature and humidity, not people. Reports refer to rooms and time periods. That also makes it easier to agree on use with data protection and the works council.

Does Nebatic help with building automation requirements?

Many non-residential buildings are expected to monitor their operation in a traceable way. Nebatic can supply data for this and document issues. Whether your building meets the requirements as a whole is something to assess with your engineering consultants.

Frequently asked questions

How to reduce energy consumption in office buildings: where should you start?

To reduce energy consumption in office buildings, start with operation rather than investment: schedules, set points, the heating curve, ventilation running at full speed and heating left on in empty zones. Many offices still run to schedules set at commissioning, while occupancy changes from day to day. Nebatic compares room data such as temperature and CO₂ with operating times and consumption, so you can see where heating and ventilation run for nobody. Changes to the systems themselves stay with your building services contractors.

What CO₂ levels in offices are acceptable?

CO₂ is the usual indicator of whether enough outdoor air reaches each person. German guidance rates CO₂ levels in offices below 1,000 ppm as no concern, 1,000 to 2,000 ppm as elevated and above 2,000 ppm as unacceptable; the UK HSE treats readings consistently above 1,500 ppm as a sign of poor ventilation. Meeting rooms often rise quickly while single offices stay unremarkable. Nebatic measures CO₂ room by room and shows which rooms tip at which times. General information, not legal advice.

CO₂ limit workplace Germany: which value applies?

There is no statutory CO₂ limit in Germany in the sense of a fixed maximum for offices. The Workplace Ordinance requires sufficient breathable air, and the technical rule ASR A3.6 "Ventilation" links CO₂ bands to measures: below 1,000 ppm no further measures, 1,000 to 2,000 ppm improve ventilation and document it, above 2,000 ppm further measures are required. Nebatic shows continuously when rooms cross these marks, as a basis for ventilation routines (not legal advice).

What affects indoor air quality in offices?

Indoor air quality in offices depends above all on how much outdoor air reaches each person, and CO₂ is the usual indicator for that. Temperature, humidity, fine particles (PM2.5) and volatile organic compounds (VOCs) complete the picture, each with its own sources, from occupancy and cleaning agents to furniture and outdoor air. Spot checks mislead, because values change with meetings and airing. Nebatic measures these values per room over days and weeks and shows which rooms stand out repeatedly.

Poor air quality in offices: symptoms – which complaints are typical?

Possible effects of poor indoor air at work include headaches, tiredness, dizziness and poor concentration, according to the German Institute for Occupational Safety and Health (IFA). Because poor air builds up gradually, the people in the room often barely notice it. Such symptoms have many possible causes and are a reason to check the building and, if needed, seek medical advice. Nebatic measures room conditions such as CO₂, temperature and humidity, not people, and does not make medical assessments.

What is sick building syndrome?

Sick building syndrome is a name for a cluster of complaints, such as headaches, tiredness and difficulty concentrating, that get better after leaving the building. The NHS describes the exact cause as unclear, with poor ventilation, dust or fumes and lighting among the likely factors. It is not a diagnosis that a sensor can make. Nebatic can show whether ventilation, temperature or humidity in the affected rooms are conspicuous, which helps to check the building; medical questions belong with a doctor.