How it works with Nebatic
Before planning, Nebatic measures temperature, humidity, CO₂ and use in the building for an agreed period. The analysis documents the current state and shows where problems lie in the fabric and where in operation. Real data thus feeds into decisions about insulation, windows, ventilation or heating.
Does not replace professional planning.
Part of the solution Audit & analysis
Frequently asked questions
What is a building analysis before refurbishment for?
A building analysis before refurbishment documents the current state with real measurements instead of assumptions. It shows whether problems such as cold rooms or damp lie in the building fabric or in operation. Within Audit & Analysis, Nebatic measures temperature, humidity, CO₂ and occupancy for an agreed period and summarises the results in a report.
How long should a measurement before refurbishment run?
A measurement before refurbishment should cover typical patterns of use and weather to be meaningful, such as working days, weekends and the heating season. The exact duration depends on the question and is agreed in advance. Nebatic plans the measurement period with you so the data can later also serve as the baseline for an after measurement.
Refurbishment or new build: how does measured data help with the decision?
Whether refurbishment or a new build makes more sense depends on the building, its use and many other factors; there is no general answer. Measured data does show how well the existing building works today and which problems can be solved in operation. Nebatic provides this current state as one basis for weighing the options with your specialists.
Planning a refurbishment with data: operational data or just building records and a site visit?
Building records and a site visit show the fabric, but without operational data, use, heating times and the actual indoor climate stay unknown. Measurements show how the building works day to day. Nebatic adds time-limited measurements and a report that supports professional planning but does not replace it.
Refurbishment roadmap for non-residential buildings: what role does measured data play?
A refurbishment roadmap arranges measures in a planned sequence so they build on each other. Measured data helps decide what to tackle first and what can already be improved in operation. Nebatic provides the measured current state and recommendations; your specialists draw up the roadmap itself.
Building inventory analysis with measured data instead of only a site visit: what is the benefit?
A conventional inventory analysis – walking the building, reviewing documents – shows its structural condition, but not how rooms are used and supplied day to day. Measurements over a longer period fill exactly this gap. Nebatic measures indoor climate and occupancy and documents anomalies as part of Audit & Analysis.
EPBD minimum energy performance standards non-residential: what do they mean for owners?
The recast EPBD requires member states to set minimum energy performance standards for non-residential buildings. Each country defines two thresholds based on its non-residential stock: all non-residential buildings must be below the 16% threshold from 2030 and below the 26% threshold from 2033, so the worst-performing buildings must be improved first. National details differ. A building analysis with measured data shows where a building really stands before you plan measures with your specialists. General information, not legal advice (as of October 2026).
What is a building renovation passport, and how does measured data help?
A building renovation passport is a document under the recast EPBD that sets out a tailored roadmap of renovation steps for a specific building, so measures build on each other over time. Member states introduce their own schemes and decide the details. Such a roadmap is only as good as the knowledge of the current state. Nebatic measures temperature, humidity, CO₂ and use for an agreed period and documents where problems lie in the fabric and where in operation, as one basis for the specialists who draw up the passport. General information, not legal advice (as of October 2026).
Deep energy retrofit or step-by-step measures: how do you decide?
A deep energy retrofit tackles envelope, heating and ventilation in one major project, while a step-by-step approach spreads measures over time. For very old or heavily altered buildings, even a new build may be on the table. Which route makes sense depends on the building, its use and many other factors. Measured data shows how the existing building works today and which problems can already be solved in operation. Nebatic provides this current state as one basis for weighing the options with your specialists.
Energy retrofit commercial building: what should be measured first?
Before an energy retrofit of a commercial building, measured operating data should help decide which measure comes first, because calculated values reflect use, controls and operating hours only roughly. Useful data includes room temperatures, humidity, CO₂, occupancy, load profiles and base load, ideally over at least one heating season. Nebatic measures for an agreed period, documents the current state and later serves as the baseline for an after measurement. It does not replace engineering design or an energy audit.
Measure before renovation building data: which values matter?
If you measure before renovation, building data should cover typical patterns of use and weather, such as working days, weekends and the heating season. Room temperature, humidity, CO₂ and occupancy show how the building is actually used and supplied, and existing consumption data adds the energy side. Nebatic plans the measurement period with you, collects the data and summarises it in a report. The same data can later serve as the baseline for checking the effect of the renovation.