Retro-commissioning: finding the causes of high heating costs

When heating costs rise, the cause is often in operation, not the fabric.

With a time-limited measurement, Nebatic shows when rooms are heated and whether that matches use.

How it works with Nebatic

For an agreed period, Nebatic measures indoor climate in the affected parts of the building and, if wanted, adds consumption data. The analysis shows when heating runs and whether it matches use, revealing typical operating causes such as unsuitable heating curves, schedules or set points. The result is prioritised starting points instead of guesses.

Part of the solution Audit & analysis

Frequently asked questions

Waste heat: what does the Energy Efficiency Act require of companies?

The EnEfG requires companies to avoid or use waste heat where technically feasible and reasonable. Knowing when and where heat arises and is needed makes it easier to find ways to use it. With room and consumption data, Nebatic shows when heating runs and whether that fits actual use. General information, not legal advice (as of October 2026).

Cutting heating costs in commercial and office space: what are typical causes of high costs?

Commercial and office spaces often share the same operational causes: heating curves set too high, schedules that do not match use, or rooms that are supplied unevenly. With Audit & Analysis, Nebatic measures the indoor climate for an agreed period and includes consumption data if you wish. The result is a report with concrete recommendations, which does not replace professional planning.

Optimising the heating curve: how do you tell it is set too high?

You need room temperatures over time: if many rooms are permanently overheated when it is mild outside, the curve is often too steep or too high. The measurement also shows which rooms stay too cold and therefore block a general reduction. Nebatic provides this data as the basis for adjustments by your heating contractor.

What does heating optimisation in an existing building involve?

Heating optimisation usually involves standard levers such as hydraulic balancing, the heating curve, set points and schedules. A measurement of room temperature and occupancy shows which of them to tackle first. Nebatic documents the current state and points out in its report where operation does not match use.

Hydraulic balancing in commercial and office space: how do you notice it is missing?

A missing hydraulic balance often shows when some rooms are overheated while others never get warm. The usual response is to raise the flow temperature, which increases costs. Nebatic's room measurement makes these differences visible; the balancing itself is carried out by your heating contractor.

How can I have buildings with high energy use analysed without starting construction work?

Analysing buildings with high energy use is best started with operation, not with construction. Nebatic measures the indoor climate for an agreed period, includes existing meter and system data and shows when and where energy is used without benefit. The report separates operational causes from those that need structural or technical planning.

Germany data centre waste heat requirements: what applies?

Under the EnEfG, a data centre is a facility with a non-redundant rated electrical connection capacity of 300 kW or more. Germany's data centre waste heat requirements apply to new facilities: those in operation from 1 July 2026 must reach an energy reuse factor of at least 10%, rising to 15% and 20% for facilities commissioned from July 2027 and July 2028, with exceptions. Nebatic does not supply data centre equipment, but can bring heat and consumption data together. General information, not legal advice (as of October 2026).

No-cost low-cost energy saving measures: which ones help with heating?

Many no-cost and low-cost energy saving measures lie in operation rather than in the building fabric: a heating curve set too high, schedules that do not match use, unsuitable set points or rooms supplied unevenly. Which of these to tackle first shows in a measurement. Nebatic measures the indoor climate for an agreed period, adds consumption data if wanted and points out where operation does not match use. The adjustments themselves are made by your heating contractor.

What is retro-commissioning, and when is it worth it?

Retro-commissioning means systematically checking the systems of an existing building and adjusting them so that they work as intended, for example controls, set points, schedules and heating curves. It is worth considering when heating costs rise without an obvious cause or rooms are supplied unevenly. Nebatic provides the data for this: a time-limited measurement shows when heating runs and whether it matches use. The adjustments are carried out by your heating contractor or system integrator.